Mechanical
Electrical
Electrical panel with its respective electrical safety: two 16A fuses at the input of the inverter, a 10A magneto thermal switch that cuts the phase and the neutral.

Electronics
DC-DC converter

Features
| Minimum Input Open-circuit voltage for turn-on | 4V |
| Maximum Input Open-circuit voltage for turn-on | 24V |
| Maximum Input Peak-Peak Voltage Ripple | N/A |
| Maximum Output Peak-Peak Voltage Ripple | ±0.4V |
| Switching Frequency | 50kHz |
| Efficiency | >85% |
| Max Input Current | 3.5A per canal |
| Max output Voltage | 15V |
Communications